9.3 FRICTION PLATE
The firction plate can be removed and inspected when
the drive system, friction plate, and axle have been
removed. Refer to the appropriate sections of this
manual for more information.
1. Disconnect the friction plate return spring, Figure
22.
2. Lift friction plate off the hex shaft.
3. Inspect for wear.
4. When reassembling apply anti-seize to the shaft
before installing the friction plate.
9.4 FRICTION PLATE HEX SHAFT
To remove the shaft (Figure 21), place the unit in the
belt service position. Remove the front half of the
frame.
1. Remove the belt from the pulley.
2. Unscrew the bolt from the pulley and remove the
pulley.
3. Remove the hub key.
4. Tip the frame forward and remove the drive
system, friction wheel, and friction plate. Refer to
appropriate sections of this manual for more
information.
5. Pull the shaft out of the bearings.
6. Reassemble in reverse order.
When installing the friction plate to the hex shaft, use
anti-seize on the shaft.
Figure 22
1
3
4
2
4
1. Friction Plate
2. Bearing Assembly
3. External Ring
4. Bearing
5. Traction Clutch
6. Return Spring
PS1051