Ariens 915131-1334 Specifications Page 26

  • Download
  • Add to my manuals
  • Print
  • Page
    / 57
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 25
GB - 26
Short Term Storage
IMPORTANT: NEVER clean unit with high-
pressure water or store unit outdoors.
Remove all dirt, grease, leaves, etc. Store in
a clean dry area.
Inspect unit for signs of wear or damage.
Ensure all fasteners are properly tightened.
Long Term Storage
Follow all instructions under Short Term
Storage.
Remove and fully charge battery. Store in a
clean dry area.
Drain fuel from fuel tank.
Refer to Engine Manual for the proper engine
storage procedures.
Touch up all scratched or chipped paint
surfaces.
Fuel System
Gasoline left in the fuel system for extended
periods without a stabilizer will deteriorate,
resulting in gum deposits in the system.
These deposits can damage the carburetor
and the fuel hoses, filter and tank. Prevent
deposits from forming in the fuel system
during storage by adding a quality fuel
stabilizer to the fuel. Follow the
recommended mix ratio found on the fuel
stabilizer container.
To treat the fuel system for storage:
1. Add fuel stabilizer (Ariens part number
00592900) according to
manufacturers’s instructions.
2. Run engine for at least 10 minutes after
adding stabilizer to allow it to reach the
carburetor.
NEVER store the engine with fuel in the fuel
tank inside of a building with potential
sources of ignition.
STORAGE
TROUBLESHOOTING
PROBLEM PROBABLE
CAUSE
CORRECTION
Engine will not
crank/start.
1. Safety interlock
system is not
engaged or is
faulty.
1. Check safety interlock system (see Safety
Interlock System on page 13).
2. Fuel tank empty. 2. Fill fuel tank (see FILLING FUEL TANK on
page 14).
3. Discharged
battery.
3. Charge battery (see Charging the Battery
on page 23).
4. Poor connection
between battery
and battery
cables.
4. Tighten battery cables and/or clean battery
and battery cables (see Cleaning Battery
and Battery Cables on page 22).
5. Spark plug wire(s)
loose or spark
plug(s) faulty.
5. Connect spark plug wire(s) or replace spark
plug(s). Refer to Engine Manual for detailed
instructions.
6. Faulty electrical
system.
6. Contact your Ariens Dealer.
7. Faulty engine. 7. Contact your Ariens Dealer.
Engine runs
rough.
1. Choke engaged. 1. Disengage choke.
2. Air filter cartridge
plugged.
2. Clean or replace air filter cartridge. Refer to
Engine Manual for detailed instructions.
3. Faulty engine. 3. Contact your Ariens Dealer.
Page view 25