Date: March 21, 2008 No. B-2037
Ariens has learned that Zoom model 915105 units in the serial number range listed above may have the
battery and solenoid ground wires connected to the screw used to mount the voltage regulator to the
engine. This location does not allow for a good battery ground, which can cause the solenoid ground wire
to overheat and lead to premature failure.
Before putting any of these units into service, inspect the voltage regulator on the front left side of the
engine. If the battery and solenoid ground wires are connected to the mounting hardware, reconnect them
to the seat spring bracket as shown in the figure on page 2. If there are no ground wires connected to the
voltage regulator mounting hardware, the unit is properly grounded and needs no further action.
Dealers who inspect and repair these units should file a warranty claim and will be reimbursed at their stan-
dard shop labor rate for 0.25 hours of labor.
Ariens Company
655 W. Ryan St.
Brillion, WI 54110-1072
www.ariens.com
Service Bulletin
Product Family: 915105
Subject: Potential Incorrect Ground Wire Location
Dealer Action: Inspect and Repair Before Putting into Service
Model Serial Number Range Description
915105 000101 – 000174 Zoom 2150
Page view 0
1 2

Summary of Contents

Page 1 - Service Bulletin

Page 1 of 2Date: March 21, 2008 No. B-2037Ariens has learned that Zoom model 915105 units in the serial number range listed above may have the bat

Page 2

Page 2 of 2Date: March 21, 2008 No. B-2037Inspect the voltage regulator mounting screw. If ground wires are connected here, move them to the seat