GB-12
Recoil Starter Handle
Pull the recoil starter handle to start the engine.
Hour Meter
Electric Start: The hour meter measures the
number of hours that the key is in the run
position and operator presence control is
engaged.
Recoil Start: The hour meter measures the number of hours
the engine has been run.
Oil Pressure Light (988104)
The red light near this symbol comes on when
the engine is running and engine oil pressure is
low. Check oil level and add if necessary. See
Engine Manual.
FILL FUEL TANK
Add fuel to the fuel tank as needed. See engine manual for
type and grade of fuel.
To add fuel to the fuel tank:
1. Put the unit in an open area.
2. Stop the engine.
3. Allow engine to cool.
4. Clean the fuel cap and the area around the fuel cap to
prevent dirt from entering the fuel tank.
5. Remove the cap from the fuel tank.
6. Fill the fuel tank. Be careful not to spill.
7. Install the cap on the fuel tank and tighten.
8. Clean up any spilled fuel before starting the engine.
TO STOP IN AN EMERGENCY
1. Release operator presence control(s).
2. Turn the ignition key Off.
3. Allow engine to stop completely.
4. Lock steering levers in neutral (988100, 101, 102, 103,
104, 110, 112).
STARTING AND SHUT OFF
Before Each Use
Check each item in Each Use in the Maintenance Schedule.
NOTE: On 988100, 101, 102, 103, 104, 110, 112 the engine
will not start unless the shift lever is in neutral and the
Power Take Off (PTO) is Off. On 988114, 115, 118, 119, 313
the engine will not start unless the Power Take Off (PTO) is
off.
Recoil Start (988100, 101, 102, 103, 110, 112)
1. Lock the steering lever latches in neutral.
2. Put the shift lever in neutral.
3. Move PTO switch to Off.
4. Set throttle to the proper starting position. If the engine
is cold, choke the engine.
5. Turn ignition switch to On.
6. Grasp recoil starter handle and pull rope out slowly
until it pulls harder. This is the compression stroke.
7. Let the rope rewind slowly.
8. Pull rope with rapid continuous full arm stroke to start
engine. Allow rope to rewind slowly.
IMPORTANT: DO NOT let starter handle snap against
engine.
9. Repeat until engine starts. (If engine does not start,
refer to Engine Manual.)
10. After engine starts, adjust choke as needed. Allow
engine to warm and run smoothly before operating
unit.
Recoil Start (988114, 115, 118, 119, 313)
1. Engage the parking brake.
2. Bring control levers to neutral.
3. Put the shift lever in neutral.
4. Move PTO switch to Off.
5. Set throttle to the proper starting position. If the engine
is cold, choke the engine.
6. Turn ignition switch to On.
7. Grasp recoil starter handle and pull rope out slowly
until it pulls harder. This is the compression stroke.
8. Let the rope rewind slowly.
9. Pull rope with rapid continuous full arm stroke to start
engine. Allow rope to rewind slowly.
IMPORTANT: DO NOT let starter handle snap against
engine.
10. Repeat until engine starts. (If engine does not start,
refer to Engine Manual.)
11. After engine starts, adjust choke as needed. Allow
engine to warm and run smoothly before operating
unit.
Electric Start (988104)
To start the engine:
1. Lock the steering lever latches in neutral.
2. Put the shift lever in neutral.
WARNING: Fuel is highly flammable and its
vapors are explosive. Handle with care. Use an
approved fuel container.
NO smoking, NO sparks, NO flames. ALWAYS
allow engine to cool before servicing.
NEVER fill fuel tank when engine is running or
hot from operation.
NEVER fill or drain fuel tank indoors.
Replace fuel cap securely and clean up spilled
fuel.
OG0620