CHECK CLUTCH OPERATION
Auger / impeller must stop within 5 seconds
when attachment clutch/impeller brake lever
is released.
Wheels must stop quickly when traction drive
clutch lever is released.
If clutches do not engage or disengage
properly, adjust or repair before operation
(see Attachment Clutch/Brake Adjustment on
page 25 and Attachment Drive Belt
Replacement on page 27).
CLEAN ENGINE
Refer to Engine Manual for detailed
instructions.
CHECK ENGINE OIL
The engine crankcase oil should be checked
every 5 hours of operation. Oil level MUST be
maintained in safe operating range on
dipstick at all times or engine damage will
result (See Engine Manual).
Park unit on a level surface. Refer to Engine
Manual for detailed instructions.
CHANGE ENGINE OIL
Refer to Engine Manual for detailed
instructions.
CHECK TIRE PRESSURE
Keep tires at pressure listed on the tire
sidewall. (see Check Tire Pressure on
page 11).
CHECK AUGER GEARCASE
(Figure 16)
IMPORTANT: Proper oil level must be
maintained.
Gear cases are filled to the correct level at
the factory. Unless there is evidence of
leakage, no additional lubricant should be
required. Check oil level each season or
every 25 hours of operation.
IMPORTANT: Be sure unit is resting on a
level surface before checking lubricant levels.
To ensure adequate lubricant level:
1. Remove filler plug and seal washer
(Figure 16). Lubricant must be 1.63 in. –
1.88 in. (4.14 cm –4.78 cm) from the flat
surface of the inspecition cover.
IMPORTANT: DO NOT remove the
inspection cover.
2. Check oil level with suitable dipstick
device. Add lubricant if required.
IMPORTANT: Use only Ariens L3 synthetic
severe duty gear lube (Part Number
00068800). Use of other lubricants will void
unit warranty.
3. Reinstall filler screw and seal washer to
200 lbf-in. (22.6 N•m).
IMPORTANT: Improper torquing or omission
of seal washer will void unit warranty.
NOTE: Replace seal washer after every 5th
inspection.
Figure 16
1. Auger Gearcase
2. Filler Plug
3. Seal Washer
OS8195
2
1
3