Ariens HVZ 915085-2350 Service Manual Page 40

  • Download
  • Add to my manuals
  • Print
  • Page
    / 53
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 39
11 - 39
Normally open contacts (big terminals) coil resistance 3.0-5.0 ohms. Contact resistance is 0.1-0.3 ohms when
correct. Electrically activated.
Coil Resistance 3.28 - 4.08 ohms.
Solenoid Off Run Start
Brown/Yellow 11.50-13.00 Volts
Small Black Connected to Ground
Large Red (Battery) 11.50-13.00 Volts 11.50-13.00 Volts 11.50-13.00 Volts
Brown/White 11.50-13.00 Volts
PTO Clutch Off Run Start
Purple/white
Black Connected To Ground
Parking Brake Switch Off Run Start
Red/Green 11.50-13.00 Volts 11.50-13.00 Volts
Yellow/Red 11.50-13.00 Volts 11.50-13.00 Volts
Brown/Yellow 11.50-13.00 Volts
Brown/White 11.50-13.00 Volts
Page view 39