Ariens 916003 - AMP 24 Specifications Page 19

  • Download
  • Add to my manuals
  • Print
  • Page
    / 36
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 18
GB - 19
CHECK CLUTCH OPERATION
Auger and impeller must stop within 5
seconds when attachment clutch/impeller
brake lever is released.
Wheels must stop quickly when traction drive
clutch lever is released.
If clutches do not engage or disengage
properly, adjust or repair before operation
(see Attachment Clutch/Brake Adjustment on
page 25 and Traction Drive Clutch
Adjustment on page 27).
CHECK CLUTCH SPRING
ADJUSTMENT
Make sure the attachment clutch and traction
drive clutch are adjusted to the range
specified in Attachment Clutch/Brake
Adjustment on page 25 and Traction Drive
Clutch Adjustment on page 27.
CHECK TIRE PRESSURE
Keep tires at pressure listed on the tire
sidewall. (see Check Tire Pressure on
page 11).
CHECK AUGER GEARCASE
IMPORTANT: Proper oil level must be
maintained.
Gear cases are filled to the correct level at
the factory. Unless there is evidence of
leakage, no additional lubricant should be
required. Check oil level each season or
every 25 hours of operation.
To ensure adequate lubricant level:
1. Remove filler plug (Figure 16). Lubricant
must be at least up to bottom of lubricant
filler hole with unit resting on a level
surface.
2. Add lubricant if required. Allow oil to
drain to level of plug and replace plug.
IMPORTANT: Use only Ariens special gear
lubricant L-2 (Part Number 00008000).
Gearcase filler plug may require an
application of Loctite® 565 thread sealant
with repeated servicing.
GENERAL LUBRICATION
Figure 17
IMPORTANT: Wipe each fitting clean before
and after lubrication. Do not wipe gearcase
filler plug; wiping the gearcase filler plug may
remove thread sealant and cause leaks.
IMPORTANT: DO NOT allow grease or oil to
get on friction disc, friction plate or belts.
NOTE: Apply Ariens Hi-Temp Grease or
equivalent to the lubrication fittings. See
SERVICE PARTS on page 31.
Sno-Thro should be lubricated (Figure 17) at
beginning of season or every 25 operating
hours.
Auger Shaft
NOTE: To grease auger shaft, remove shear
bolt nuts, and shear bolts. Apply grease at the
grease zerks and then turn the auger
assemblies on the auger shaft. Replace
shear bolts per instructions in Shear Bolts on
page 21.
Figure 16
1. Auger Gearcase
2. Filler Plug
OS2600
1
2
Page view 18