3. Check mower blade balance.
Slide mower blade on an unthreaded
bolt. A balanced blade should remain in
a horizontal position. If either end of
mower blade moves downward, sharpen
the heavy end until blade is balanced
(Figure 17).
4. Install mower blade on unit.
5. Tighten the bolts to a torque of 37.5 -
50 lbf-ft (51-68 N•m).
CHECK DRIVE BELT (SELF-
PROPELLED MODELS)
Check drive belt and replace if worn or
damaged. See DRIVE BELT
REPLACEMENT (self-propelled models) on
page 21.
CHECK FASTENERS
Check all fasteners for proper tightness. Pay
special attention to blade hardware and all
guards, shields and safety devices.
CHECK AIR CLEANER
See engine manual for specific information.
CHANGE ENGINE OIL
IMPORTANT: Change engine crankcase oil
after first five (5) hours of operation. Then
change oil after every 25 hours of operation.
Refer to engine manual for instructions and
proper oil type.
IMPORTANT: Proper oil level must be
maintained at all times or engine damage will
result. DO NOT overfill. Be sure engine is
level when adding oil.
REPLACE OIL FILTER
(KAWASAKI ENGINES)
Replace oil filter every 100 hours of use or
every season.
1. Change engine oil.
2. Clean around filter.
3. Turn filter counterclockwise to remove
(Figure 18).
4. Apply a thin coat of oil onto seal of new
filter.
5. Install new filter and hand tighten
securely.
GENERAL LUBRICATION
NOTE: The mower transmission is lubricated
and sealed at the factory. It should need no
routine lubrication. If the transmission leaks
grease, bring the mower to your local Ariens
dealer for repair.
CHECK SPARK PLUG
Spark plug should be replaced every 100
hours of operation or each year.
NOTE: Loose spark plug wire terminals can
cause sparking. Replace terminal if
damaged.
CHECK ENGINE COOLING
To prevent overheating, air must circulate
freely around the cooling fins, cylinder head
and block.
Every 100 hours of operation or yearly (more
often if conditions require) remove blower
housing and clean cooling fins. See engine
manual for instructions.
Figure 17
OA0013
Bolt
Blade
WARNING: HOT SURFACES can
cause death or serious injury. DO
NOT TOUCH parts which are hot
from operation. ALWAYS allow
parts to cool.
Figure 18